UL 94 Standard

UL 94, the Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing.

HB: slow burning on a horizontal specimen; burning rate < 76 mm/min for thickness < 3 mm or burning stops before 100 mm.

V-0: burning stops within 10 seconds on a vertical specimen; drips of particles allowed as long as they are not inflamed.

V-1: burning stops within 30 seconds on a vertical specimen; drips of particles allowed as long as they are not inflamed.

V-2: burning stops within 30 seconds on a vertical specimen; drips of flaming particles are allowed.

UL94 Vertical Burn Test Diagram

IP Ratings Explained

IP (Ingress Protection) ratings are defined in international standard EN 60529. They define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies and moisture.

IP RatingIngress of solid objects (First Digit)Ingress of liquids/moisture (Second Digit)
0No protectionNo protection
1Protected against solid objects over 50mmProtected against vertically falling drops of water
2Protected against solid objects over 12.5mmProtected against falling drops when tilted up to 15°
3Protected against solid objects over 2.5mmProtected against sprays of water up to 60°
4Protected against solid objects over 1.0mmProtected against splash water from any direction
5Limited protection against dust ingressProtected against low pressure water jets from any direction
6Totally protected against dust ingressProtected against high pressure water jets from any direction
7N/AProtected against short periods of immersion in water
8N/AProtected against long, durable periods of immersion in water
9N/AProtected against close-range high pressure, high temperature spray downs

Important Note:

Our enclosures are not Ingress Protection certified. These details are given only for information purpose.